{"id":312,"date":"2012-11-01T20:13:17","date_gmt":"2012-11-01T20:13:17","guid":{"rendered":"http:\/\/www.fiberlitetech.com\/blog\/?p=312"},"modified":"2012-11-01T20:13:17","modified_gmt":"2012-11-01T20:13:17","slug":"optimum-value-engineering-and-cellulose-insulation","status":"publish","type":"post","link":"https:\/\/www.fiberlitetech.com\/blog\/optimum-value-engineering-and-cellulose-insulation\/","title":{"rendered":"Optimum Value Engineering and Cellulose Insulation"},"content":{"rendered":"<p>Building experts have performed considerable research on ways to reduce the amount of framing in our homes.\u00a0 The U.S. Forestry Products Association and other organizations have devised a framing system using Optimum Value Engineering (O.V.E.) that reduces unnecessary framing, yet maintains structural integrity.\u00a0 The goals of O.V.E. are to:<\/p>\n<p>Reduce framing time and lower construction costs<\/p>\n<p>Save on increasingly scarce dimensional framing lumber<\/p>\n<p>Increase energy efficiency allowing more space for insulation and reducing annual energy costs<!--more--><\/p>\n<p>Many builders have been resistant to adopt O.V.E. practices due to concerns about compromising structural integrity.\u00a0 With quality installations, the home\u2019s framing strength should not be altered by O.V.E.\u00a0\u00a0 Approaches include:<\/p>\n<p>Less corner framing<\/p>\n<p>Less framing around partition walls<\/p>\n<p>More energy-efficient headers<\/p>\n<p>Eliminating curtailed studs (cripples)<\/p>\n<p>Using single top plates via point loading<\/p>\n<table style=\"width: 494px; height: 28px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"162\">Comparison<\/td>\n<td valign=\"top\" width=\"162\">Standard<\/td>\n<td valign=\"top\" width=\"162\">O.V.E.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Insulation Voids\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a03%\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a00%<\/p>\n<p>Framing Factor\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 15-25%\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a010-15%<\/p>\n<p>Sheathing R-Value\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0 R-0.5 to 2.0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0R-2.5<\/p>\n<p>Effective Average R-Value\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 R-11.1\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 R-14.6 (30% higher)<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignleft  wp-image-318\" title=\"Blog Image 1\" src=\"https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-11.jpg\" alt=\"\" width=\"605\" height=\"401\" srcset=\"https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-11.jpg 1009w, https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-11-150x99.jpg 150w, https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-11-300x198.jpg 300w, https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-11-452x300.jpg 452w\" sizes=\"(max-width: 605px) 100vw, 605px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignleft  wp-image-319\" title=\"Blog Image 2\" src=\"https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-2.jpg\" alt=\"\" width=\"652\" height=\"905\" srcset=\"https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-2.jpg 1087w, https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-2-108x150.jpg 108w, https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-2-216x300.jpg 216w, https:\/\/www.fiberlitetech.com\/blog\/wp-content\/uploads\/2012\/10\/Blog-Image-2-737x1024.jpg 737w\" sizes=\"(max-width: 652px) 100vw, 652px\" \/>Walls are the most complex component of the building envelope to insulate, air seal, and control moisture.\u00a0 The keys to an effective wall are:<\/p>\n<p>Airtight construction-all air leaks sealed in the wall during construction and prior to insulation installation.<\/p>\n<p>Moisture control-exterior rain drainage system, continuous air barrier, vapor barrier on the appropriate side of the wall.<\/p>\n<p>Complete insulation coverage-O.V.E. framing to maximize insulation coverage, no gaps or voids in cavity, continuous insulated sheathing.<\/p>\n<p>Cellulose insulation applied in the walls delivers maximum thermal performance by sealing all voids and gaps and virtually eliminates air infiltration.\u00a0 While air sealing is imperative, controlling moisture improves the effectiveness of the insulation.\u00a0 It is a myth that installing <a href=\"https:\/\/www.fiberlitetech.com\/Fiberlite-Technologies-2nd.php?pagename=Industry-Professionals-Air-Vapor-Barriers\">vapor barriers<\/a> is the most important step for controlling moisture in the walls. Moisture moves in two ways:\u00a0 air movement and diffusion.\u00a0 By blocking the movement of moisture-laden air, cellulose insulation reduces moisture movement to manageable levels within a home or building.<\/p>\n<p>There are many advantages in using the Optimum Value Engineering method and Cellulose Insulation.\u00a0 Homes are more energy efficient and feel more comfortable.\u00a0 The thermal performance of cellulose applied in the walls allows for a stable temperature.\u00a0 The indoor humidity is also better controlled, and drafts are reduced.\u00a0 They are also very quiet because the extra insulation and tight construction keeps the exterior noise out.<\/p>\n<p>If you are building a home or office, consider using the Optimum Value Engineering method of construction and Cellulose Insulation!<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Building experts have performed considerable research on ways to reduce the amount of framing in our homes.\u00a0 The U.S. Forestry Products Association and other organizations have devised a framing system using Optimum Value Engineering (O.V.E.) that reduces unnecessary framing, yet &hellip; <a class=\"more-link\" href=\"https:\/\/www.fiberlitetech.com\/blog\/optimum-value-engineering-and-cellulose-insulation\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1000,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[7,6],"tags":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/posts\/312"}],"collection":[{"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/users\/1000"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/comments?post=312"}],"version-history":[{"count":10,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/posts\/312\/revisions"}],"predecessor-version":[{"id":328,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/posts\/312\/revisions\/328"}],"wp:attachment":[{"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/media?parent=312"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/categories?post=312"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/tags?post=312"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}