{"id":341,"date":"2012-11-19T13:49:00","date_gmt":"2012-11-19T13:49:00","guid":{"rendered":"http:\/\/www.fiberlitetech.com\/blog\/?p=341"},"modified":"2012-11-19T13:49:00","modified_gmt":"2012-11-19T13:49:00","slug":"test-your-knowledge-answers","status":"publish","type":"post","link":"https:\/\/www.fiberlitetech.com\/blog\/test-your-knowledge-answers\/","title":{"rendered":"Test Your Knowledge Answers:"},"content":{"rendered":"<ol>\n<li>Which of the following ASTM Test is required for all loose-fill cellulose insulation?<\/li>\n<\/ol>\n<p style=\"padding-left: 30px;\">\u00a0\u00a0\u00a0\u00a0 <strong>b. ASTM C-739<\/strong><\/p>\n<p style=\"padding-left: 60px;\"><em>The standard for loose-fill is ASTM C-739, which provides test for R-Value, odor, moisture vapor absorption, and fungi resistance, as well as critical radian flux,\u00a0 smoldering, combustion, corrosiveness, and settled density.<\/em><\/p>\n<p style=\"padding-left: 30px;\"><em>2.\u00a0 <\/em>When building a blocking device around heat-producing fixtures, the clearance around these fixtures must be a minimum of:<\/p>\n<p style=\"padding-left: 30px;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <strong>b. 3 inches<\/strong><\/p>\n<p style=\"padding-left: 60px;\">\u00a0<em>Blocking should be permanently placed so as to keep insulation a minimum of three inches away from all sides of recessed lighting fixtures and other heat- producing devises.<\/em><\/p>\n<p style=\"padding-left: 30px;\">3.\u00a0 Which of the following products is<span style=\"text-decoration: underline;\"><strong> not<\/strong><\/span> an approved material for blocking the soffit\/top plate area of the roof and wall system?<\/p>\n<p style=\"padding-left: 30px;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <strong>c. Plastic (any type)<\/strong><\/p>\n<p style=\"padding-left: 60px;\"><em>\u00a0The following materials are approved materials for blocking soffit\/top plate area of the roof and wall system:\u00a0 1) windblock product or moisture resistant\u00a0\u00a0\u00a0\u00a0 cardboard installed to the outside edge of the top plate, 2) batt insulation with the paper facing the outside soffit, 3) anchored foam board.<\/em><\/p>\n<p style=\"padding-left: 30px;\">4.\u00a0 Heat is moved by what method?<\/p>\n<p style=\"padding-left: 30px;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <strong>d. All the above<\/strong><\/p>\n<p style=\"padding-left: 60px;\">\u00a0<em>Buildings respond to three types of heat transfer-conduction, convection and radiation.\u00a0 Conduction occurs by direct contact.\u00a0 Convection is heat transfer that occurs when a substance is in a gaseous state.\u00a0 Radiation is the type of heat transfer that you cannot see but can feel.<\/em><\/p>\n<p style=\"padding-left: 30px;\">5.\u00a0 The installer must provide a signed and dated statement describing the insulation installed and stating:<\/p>\n<p style=\"padding-left: 30px;\">\u00a0\u00a0\u00a0\u00a0\u00a0 <strong>e. All the above<\/strong><\/p>\n<p style=\"padding-left: 60px;\">\u00a0<em>The FTC Rule 16 CFR 460 required the insulation contractor to provide a signed and dated statement describing the insulation installed, stating the thickness, coverage area, R-Value and number of bags used.<\/em><\/p>\n<p style=\"padding-left: 60px;\">\n","protected":false},"excerpt":{"rendered":"<p>Which of the following ASTM Test is required for all loose-fill cellulose insulation? \u00a0\u00a0\u00a0\u00a0 b. ASTM C-739 The standard for loose-fill is ASTM C-739, which provides test for R-Value, odor, moisture vapor absorption, and fungi resistance, as well as critical &hellip; <a class=\"more-link\" href=\"https:\/\/www.fiberlitetech.com\/blog\/test-your-knowledge-answers\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[6],"tags":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/posts\/341"}],"collection":[{"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/comments?post=341"}],"version-history":[{"count":8,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/posts\/341\/revisions"}],"predecessor-version":[{"id":349,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/posts\/341\/revisions\/349"}],"wp:attachment":[{"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/media?parent=341"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/categories?post=341"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fiberlitetech.com\/blog\/wp-json\/wp\/v2\/tags?post=341"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}